{"product_id":"nastec-mida-406-pump-inverter-controller-3hp-3x400v","title":"NASTEC MIDA 406 Pump Inverter Controller – up to 3 HP (3×400V)","description":"\u003cp\u003e\u003cstrong\u003eThe NASTEC MIDA 406 is a smart pump inverter controller designed to automatically manage and protect your water pump.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUpgrade your existing pump system without replacing your pump.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt uses variable speed technology to adjust motor performance based on water demand, ensuring stable pressure, improved efficiency, and longer pump life.\u003c\/p\u003e\n\u003cp\u003eUnlike traditional fixed-speed control systems, MIDA continuously adapts pump operation to real working conditions, reducing energy consumption and preventing common issues such as pressure fluctuations and pump damage.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"display: inline-flex; align-items: center; gap: 5px;\"\u003e\u003cimg style=\"width: 16px; height: 11px;\" src=\"https:\/\/upload.wikimedia.org\/wikipedia\/en\/0\/03\/Flag_of_Italy.svg\"\u003e 100% Made in Italy\u003c\/span\u003e – engineered and manufactured for maximum reliability and long-term performance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWorks with almost any AC water pump, in both new and existing systems.\u003c\/p\u003e\n\u003ch3 data-end=\"871\" data-start=\"843\" data-section-id=\"o05as0\"\u003eApplications \u0026amp; Compatibility:\u003c\/h3\u003e\n\u003cul data-end=\"1117\" data-start=\"873\"\u003e\n\u003cli data-end=\"914\" data-start=\"873\" data-section-id=\"18v7kqh\"\u003eDomestic and residential water supply\u003c\/li\u003e\n\u003cli data-end=\"947\" data-start=\"915\" data-section-id=\"7f5ghu\"\u003eBooster and pressure systems\u003c\/li\u003e\n\u003cli data-end=\"983\" data-start=\"948\" data-section-id=\"1ukvjjx\"\u003eAgricultural irrigation systems\u003c\/li\u003e\n\u003cli data-end=\"1012\" data-start=\"984\" data-section-id=\"17626y4\"\u003eIndustrial water systems\u003c\/li\u003e\n\u003cli data-end=\"1051\" data-start=\"1013\" data-section-id=\"1xtxyej\"\u003ePublic water distribution networks\u003c\/li\u003e\n\u003cli data-end=\"1088\" data-start=\"1052\" data-section-id=\"1ro3jbt\"\u003eSwimming pool and fountain pumps\u003c\/li\u003e\n\u003cli data-end=\"1117\" data-start=\"1089\" data-section-id=\"rh3pod\"\u003eHVAC circulation systems\u003c\/li\u003e\n\u003cli data-end=\"1117\" data-start=\"1089\" data-section-id=\"rh3pod\"\u003eSurface pumps\u003c\/li\u003e\n\u003cli data-end=\"1117\" data-start=\"1089\" data-section-id=\"rh3pod\"\u003eSubmersible pumps\u003c\/li\u003e\n\u003cli data-end=\"1117\" data-start=\"1089\" data-section-id=\"rh3pod\"\u003eCentrifugal and multistage pumps\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eMulti-Pump Systems \u0026amp; Booster Applications\u003c\/h3\u003e\n\u003cp\u003eMIDA can be used not only with single pumps, but also in \u003cstrong\u003emulti-pump systems\u003c\/strong\u003e, allowing multiple pumps to work together automatically.\u003c\/p\u003e\n\u003cp\u003eIn traditional booster systems, pumps start and stop frequently, often requiring pressure tanks and causing pressure fluctuations, mechanical stress, and higher energy consumption.\u003c\/p\u003e\n\u003cp\u003eWith MIDA, pumps operate with \u003cstrong\u003evariable speed control\u003c\/strong\u003e, maintaining constant pressure without continuous start\/stop cycles.\u003c\/p\u003e\n\u003cp\u003eMultiple pumps can be connected and managed together (combo mode), automatically adapting to system demand and improving overall efficiency and reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e✔ Key advantages in multi-pump systems:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eStable pressure without frequent pump start\/stop\u003c\/li\u003e\n\u003cli\u003eReduced need for large pressure tanks\u003c\/li\u003e\n\u003cli\u003eLower mechanical stress on pumps and system\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eProtects the motor from excessive start\/stop cycles\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eExtends motor and pump lifetime\u003c\/li\u003e\n\u003cli\u003eImproved energy efficiency\u003c\/li\u003e\n\u003cli\u003eAutomatic load distribution between pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3 data-end=\"452\" data-start=\"430\" data-section-id=\"xivs1i\"\u003eElectrical Data:\u003c\/h3\u003e\n\u003cul data-end=\"645\" data-start=\"453\"\u003e\n\u003cli data-end=\"586\" data-start=\"550\"\u003ePower supply: 3 × 380\/400V AC (±10%)\u003c\/li\u003e\n\u003cli data-end=\"610\" data-start=\"587\"\u003eFrequency: 50–60 Hz\u003c\/li\u003e\n\u003cli data-end=\"712\" data-start=\"611\"\u003eMax motor power:\n\u003cul data-end=\"712\" data-start=\"634\"\u003e\n\u003cli data-end=\"671\" data-start=\"634\"\u003eUp to 2.2 kW (3 HP) \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"779\" data-start=\"713\"\u003eMax output current:\n\u003cul data-end=\"779\" data-start=\"739\"\u003e\n\u003cli data-end=\"758\" data-start=\"739\"\u003e6 A \u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"809\" data-start=\"780\"\u003eOutput frequency: 0–50 Hz\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"702\" data-start=\"647\"\u003e\u003cstrong data-end=\"702\" data-start=\"647\"\u003eCompatible with all 3×400V pump motors.\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr data-end=\"707\" data-start=\"704\"\u003e\n\u003ch3 data-end=\"735\" data-start=\"709\" data-section-id=\"1rpnrsh\"\u003eProtection \u0026amp; Safety:\u003c\/h3\u003e\n\u003cul data-end=\"877\" data-start=\"736\"\u003e\n\u003cli data-end=\"762\" data-start=\"736\" data-section-id=\"1gqtx1f\"\u003eDry running protection\u003c\/li\u003e\n\u003cli data-end=\"802\" data-start=\"763\" data-section-id=\"y1hz0v\"\u003eOverload and overcurrent protection\u003c\/li\u003e\n\u003cli data-end=\"846\" data-start=\"803\" data-section-id=\"1fvjjae\"\u003eOvervoltage and undervoltage protection\u003c\/li\u003e\n\u003cli data-end=\"877\" data-start=\"847\" data-section-id=\"x75895\"\u003eOvertemperature protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"882\" data-start=\"879\"\u003e\n\u003ch3 data-end=\"912\" data-start=\"884\" data-section-id=\"ikj7g1\"\u003ePerformance \u0026amp; Control:\u003c\/h3\u003e\n\u003cul data-end=\"1059\" data-start=\"913\"\u003e\n\u003cli data-end=\"956\" data-start=\"913\" data-section-id=\"xj2hzx\"\u003eVariable speed control (VFD technology)\u003c\/li\u003e\n\u003cli data-end=\"988\" data-start=\"957\" data-section-id=\"13ar812\"\u003eConstant pressure operation\u003c\/li\u003e\n\u003cli data-end=\"1017\" data-start=\"989\" data-section-id=\"1l05ycb\"\u003eSoft start and soft stop\u003c\/li\u003e\n\u003cli data-end=\"1059\" data-start=\"1018\" data-section-id=\"1fudjh5\"\u003eAutomatic restart after power failure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-end=\"1064\" data-start=\"1061\"\u003e\n\u003ch3 data-end=\"1099\" data-start=\"1066\" data-section-id=\"19swyh3\"\u003eInstallation \u0026amp; Environment:\u003c\/h3\u003e\n\u003cul data-end=\"1300\" data-start=\"1100\"\u003e\n\u003cli data-end=\"1137\" data-start=\"1100\" data-section-id=\"5sltxh\"\u003eProtection rating: IP66 (NEMA 4X)\u003c\/li\u003e\n\u003cli data-end=\"1179\" data-start=\"1138\" data-section-id=\"h7nkux\"\u003eOperating temperature: -10°C to +60°C\u003c\/li\u003e\n\u003cli data-end=\"1225\" data-start=\"1180\" data-section-id=\"pwyynl\"\u003eMax ambient temperature (full load): 40°C\u003c\/li\u003e\n\u003cli data-end=\"1263\" data-start=\"1226\" data-section-id=\"e31vba\"\u003eMax installation altitude: 1000 m\u003c\/li\u003e\n\u003cli data-end=\"1300\" data-start=\"1264\" data-section-id=\"15qqes9\"\u003eHumidity: 5–95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMax. Altitude at Full Load: 1000 m\u003c\/li\u003e\n\u003cli\u003eRelative Humidity: 5–95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWidth (W): 150 mm\u003c\/li\u003e\n\u003cli\u003eDepth (D): 211 mm\u003c\/li\u003e\n\u003cli\u003eHeight (H): 130 mm\u003c\/li\u003e\n\u003cli\u003eNet Weight: approx. 2.5 kg\u003c\/li\u003e\n\u003cli\u003eIncludes: Kit Wall Mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ch3\u003eConnectivity \u0026amp; I\/O\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRS485 MODBUS RTU – for BMS\/SCADA integration\u003c\/li\u003e\n\u003cli\u003eBACnet protocol support\u003c\/li\u003e\n\u003cli\u003eBluetooth® SMART – wireless setup and monitoring via smartphone\u003c\/li\u003e\n\u003cli\u003e2 x Analog inputs (4–20 mA or 0–10 VDC)\u003c\/li\u003e\n\u003cli\u003e4 x Digital inputs (N.O. or N.C.)\u003c\/li\u003e\n\u003cli\u003e2 x Settable digital outputs – motor run signal and alarm signal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCE certified\u003c\/li\u003e\n\u003cli\u003eEMC compliant (EN61800-3 C2)\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"NASTEC","offers":[{"title":"Default Title","offer_id":47584301940962,"sku":"3070300110","price":38900.0,"currency_code":"THB","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0802\/5358\/3586\/files\/MIDA1-ph1.jpg?v=1773738195","url":"https:\/\/abotrading.store\/products\/nastec-mida-406-pump-inverter-controller-3hp-3x400v","provider":"ABO Trading","version":"1.0","type":"link"}